Описание

  • Read head with guard locking
  • Locking force up to 6500 N
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • 2 LEDs (2 freely configurable)
  • Approach direction A (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage
  • DC 24 V +10% -15%
Guard locking type
CET1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.
LED function display
LED rotfreely configurable
LED grunfreely configurable
Category according to EN ISO 13849-1 Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position. Notes
  • Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
  • The device may be operated only in conjunction with the actuator CET-A-.... The actuator must be ordered separately.
Auxiliary release Is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer). Dimension drawing Block diagram Dimension drawingBlock diagram Technical dataApprovals Mechanical values and environment
Housing material
Slide Stainless steel
Safety switch Die-cast aluminum
Weight
Net 1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP67
Mechanical life 1 x 106
Installation orientation Any
Degree of freedom
X ±5 mm
Y ±5 mm
Z ±4 mm
Switching frequency 1 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 6500 N
Locking force FZh 5000 N
Electrical connection ratings
Operating voltage DC
LED 24 V DC -15% ... 15% Reverse polarity protected
Current consumption
ICM 480 mA Solenoid
LED max.6 mA
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 1,5 kV
Power consumption
Solenoid 12 W
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
''